(PATENT PENDING) FOR TESTING SEGREGATION POTENTIAL, FLOW RATE AND SIEVE ANALYSIS OF POWDERS ![]() MAIN UNIT ![]() OPTIONAL ACCESSORIES
Segregation potential of a powder or powder blend can be
determined by agitation and/or vibration and unit-dose samples
are removed at pre-determined intervals for chemical content
uniformity analysis or particle size analysis.
The unit-dose powder samples can be compacted into tablets in the sampling die itself by using a patented technique in order to reduce the sampling error, which is critical for obtaining reliable results from this apparatus. The sample tablets can be submitted to the laboratory for content uniformity analysis. An optional NIR device will be available in the future for in-line sample analysis. The results can be displayed as a table or plotted as a graph of relative standard deviation (or coefficient of variation, %) versus time. This test can be repeated at different settings of the agitator and the vibration device. Flow rate of a powder or powder blend can be determined by letting powder flow from the hopper at a pre-set gate opening. The scale records the weights and transmits the data to the PLC. The results will be plotted as incremental weight versus time. Average flow rate and RSD are computed. The effect of agitation and/or vibration on powder flow rate and uniformity of flow may also be studied. Particle size distribution can be determined by using standard sonic sifter screens. The screens are stacked in a screen holder, clamped and attached to the vibration device saddle. This attachment replaces the hopper when this test is done. Sonic as well as electromechanical vibration is used to affect sifting for a pre-set time period. After the test is done, the screen stack is simply put on the scale and one screen is removed at a time and ENTER is pressed on the touch screen. PLC automatically determines the weight of the material retained on each screen from the data of the weights of the blank screens entered previously. Particle size distribution is displayed as histogram, frequency distribution curve and log-probability curve. Median particle size is computed and displayed on the screen. The data obtained on this apparatus are in agreement with the data from standard sonic sifters.
Main apparatus includes:
Optional accessories include:
Dimensions: Main apparatus: 16"W x 28"D x 41"H (including the agitator motor) Console: 12.5"W x 12.5"D x 9.0"H Net weight: About 40 lbs Electrical: 110V/60Hz or 220V/1 Phase/50Hz |
![]() |
MAXI-BLEND is a product of GlobePharma, Inc., P.O. Box 10837 New Brunswick, NJ 08906-9998 Tel: 732-819-0381 Fax: 732-777-5129 Email: sanni@globepharma.com www.globepharma.com |